Product Description
saveBOARD Exposed internal wall & ceiling lining is a semi vapour permeable structural composite panel made from 100% shredded and compressed composite packaging. No water, glues, resins are used during the manufacture process. saveBOARD Exposed is finished with a clear recycled plastic face and recycled paper back.
Not Perfect
saveBOARD products are made from 100% recycled waste and as such are not perfect. The dimensional tolerance is + / - 1mm and the weight + / - 10%/sheet.
The surface of Exposed may have veins or press marks, the paper backing may have creases and some air bubbles may be evident.
The colour will vary slightly from batch to batch due to the varying nature of the raw materials to manufacture saveBOARD, namely recycled waste. The colour may also vary slightly from a sample or between batches.
These are standard characteristics of a saveBOARD product. More information can be found here on the website (Not Perfect).
Scope of Use:
-
As an internal wall lining or partition or a ceiling lining.
-
Where Materials Group 3 is required.
-
On a timber frame.
Limitations:
-
Not suitable for wet areas as defined by the NCC Schedule 1.
-
Do not use in exterior applications.
-
Check compatibility with any glues, resins or sealants to be used in conjunction with Exposed.
-
Framing to be at a moisture content < 16% before internal linings are applied. This is a saveBOARD warranty requirement.
Handling
When manually handling saveBOARD Exposed ensure the panels are lifted correctly. For safety, we recommend a minimum of 2 people.
Storage
Store internally only. Lay flat on suitable bearers. The spacing between the bearers should be no more than 600mm apart.
It is good to trade practice to allow sheet materials to climatize to the site conditions for 48 hours prior to Installation.
Maintenance & Warranty
Exposed pre-finished panels are inherently impact resistant, durable and suitable for high contact areas with a wipe down surface.
Please refer to the Maintenance & Warranty (15yrs) documents on the saveBOARD website: www.saveboard.com.au/exposed-internal
Installation Instructions:
Working safely with saveBOARD
All saveBOARD products are safe to work and live with. All saveBOARD products are Volatile Organic Compounds (V.O.C.'s) and formaldehyde free.
saveBOARD can be cut, drilled, and sanded in the same manner and methods as most wood-based products.
Cutting saveBOARD does not create any toxic dust, vapors, or other potentially harmful inhalants, but we recommend you always follow Health & Safety best practices.
A Material Safety Data Sheet is available on the website.
Cutting & Drilling
saveBOARD Exposed can be cut in the same manner and methods as most wood-based products with a hand saw or power tools.
For handsaw cutting, a standard 500mm Handsaw with a > 7 Teeth Per Inch (T.P.I.) is suitable.
Power tools; a circular saw with > 1200w motor fitted with a standard ripping blade > 40 Teeth is recommended.
Clean up the cut with a sandpaper block/ 80 Grade sandpaper or as required.
T.I.P. – Allow the hole saw to cut. Do not apply excessive pressure as this may damage the back of the board upon exit.
Framing
All support timber framing should comply with AS 1684 or AS1720 or with the Specific Engineering Design (S.E.D.) requirements. 90 x 45mm is the minimum timber framing size recommended for saveBOARD.
Termite Resistance
saveBOARD is naturally termite resistant and has been tested with subterranean termites (Coptotermes formosanus). Samples of saveBOARD have been placed on termite nests with a control (untreated wood) and no loss of material was observed. No secondary treatment is required using chemicals or similar.
There are also published papers studying composite boards made from waste Tetra Pak packaging materials (same composition as saveBOARD), which have tested the boards for fungal decay and termite resistance. These studies have concluded that the panels were resistant against mould, fungi and termites. A copy of this paper can be found here.

saveBOARD Exposed internal wall linings should be fixed at 400mm stud centres
Installing on to Walls
Install the boards vertically and plumb at 400mm centres, ensuring that the sheet edges have a minimum of 18 mm edge cover over the framing. Install with a 6 mm–10 mm clearance above the finished floor level when skirting boards are to be used. Ensure all wall insulation is installed back or flush from the framing face to be lined.
On a timber frame use 40 mm panel pins or 6 g screws at 150 mm centres around the sheet perimeter and 300 mm centres through the body of the sheet for non-structural applications.
As a Ceiling Lining Install the boards to ceilings Install the boards in a staggered pattern at 90° to the ceiling rafters or ceiling battens. Ensure that the sheet ends meet over supporting timber and that ceiling battens centres do not exceed 450 mm. Any free edges between battens need to be back blocked.
Metal ceiling battens need to a minimum of .75mm and used in conjunction with supplier recommend metal screws otherwise the batten may strip as the screws are countersunk into the surface of the board.
General
Heat Do not install the boards adjacent to, or behind heat source.
Adhesives
For paper back, common structural adhesives can be used in small daubs at 300 mm centres on the central studs for structural and non-structural board installations. An aluminum or plastic jointer may be used for aesthetic purposes. Recommended adhesives Selleys Liquid Nails or SikaBond.
For exposed back, you must use Soudal Multibond SMX35 when gluing onto timber or steel studs.
Check compatibility.
Jointing
For further detail refer to our Jointing Guide that can be found on the website (Technical Literature).

Edges and Corners
External Corner – Use an extrusion or trim
Internal Corners – Butt Join and silicon
Top edge - Butt join or use architrave or an extrusion to protect the edge
Bottom Edge –Use skirting or an extrusion to protect the edge.